Handy & Air Cooled Dry Pump NeoDry Gシリーズ

Maintenance cycle; Once in 3 years!(Approx. when Air/N2 is used) No Tip-seal replacement, No Performance deterioration, No Particles! No Oil smoke, No chamber contamination! Hassle free to replace rotary/scroll pumps! Condensation-prone gas, like water vapor or solvent, available! By virtue of inverter, frequency does not affect to performance! Low noise, low vibration!

Features

New Design !

Major Products

Spec. / Products NeoDry7GNeoDry15GNeoDry30GNeoDry36G
Max. pumping speed
[L/min]
110250500600
Ultimate pressure [Pa]
(Without gas ballast)
5.01.00.7
Supply voltage
(50/60Hz)
Single Phase, AC100-240V
Gas ballast mechanismOptional (N2 model is available)
Max allowable moisture[g/h]
(With gas ballast)
135275350
Noise [dB(A)]
(Inlet closed)
4551
Vibration [μmp-p]
(Inlet closed)
≦8
Mass [kg]19222451
Inlet sizeNW25NW40
Outlet sizeNW25
Power consumption
at ultimate pressure [kW]
0.280.340.55
Dimensions [mm]
L×W×H
360×196×196385×210×219410×210×219475×298×260

S-P Curve

S-P Curve

* S-P curves vary by combination.

PDF Document

  1. Because we are constantly working to improve performance and upgrade our products, specifications and diagrammatic representations in this catalog may change without notice.
  2. Products displayed in this catalog must be approved for export in accordance with the Foreign Exchange and Foreign Trade Control Act. Before placing an export order, please contact our Business Department.

mail address for inquiries: sales@kashiyama.com